Menu
Your Cart

Blue gate 3KVA Online UPS

Blue gate 3KVA Online UPS UPS image
Blue gate 3KVA Online UPS
  • Stock: In Stock
  • Model: BG3000
  • Weight: 10.00kg
190 samples sold
₦649,000
Price may vary,contact us

OVERVIEW OF BLUEGATE ONLINE 3KVA UPS:

This UPS is a sophisticated piece of equipment with central processing system. It is equipped with advanced voltage compensation technology, advanced frequency technology and advanced PFC technology all to produce an undistorted standard sine wave from a wide range of input variables. Its zero transfer ability is suited forapplication that requires seamless input parameters.


SPECIFICATION:

  • High frequency and double conversion online technology
  • Fully digitized microprocessor control
  • Wide input voltage range
  • LCD display
  • UPS start up without battery (for 1-3KVA)
  • Cold start
  • Advanced battery management
  • Automatic battery charging in UPS off mode
  • Lightning and surge protection
  • Short circuit and overload protection
  • Fan speed auto control when loads varies
  • Network/fax/modem surge protection (for 1-3KVA)
  • Optional extension battery pack
  • Battery voltage display
  • Load capacity display
  • EMI/RFI noise filter
  • Smart RS232 communication with monitoring software
  • Optional SNMP card slot
  • EPO function (optional)
  • Input L and N reversed alarm function (for 1-3KVA)
  • Parallel capacity (for 6-10KVA)
  • Model: BGK 3.0HFi
  • Capacity: 3KVA/2100W
  • Voltage Range When load<70%, input range is 115±5VAC - 295±5VAC
  • Voltage Range When Load≥70%, input range is 160±5VAC - 295±55VAC
  • Frequency Range: 46 - 54Hz±0.5Hz or 56 - 64Hz±0.5Hz auto-sensing
  • Phase: Single phase
  • Power Factor: ≥0.97
  • Voltage Range: 220/230Vac ±2%
  • Phase: Single Phase
  • Frequency Range: Synchronise with the utility on AC mode; 50Hz/60Hz±0.2% on battery mode
  • THD(linear load): <3%
  • THD(non-linear load): <6%
  • Load capability: >110%, 30s turn to bypass mode; >150%, 300ms turn to bypass mode
  • Crest Factor: 3:01
  • Short circuit protection: 5 cycles turn off the inverter, no transfer to bypass, provide alarm (AC mode). 5 cycles turn off the inverter, provides an alarm(battery mode). Input fuse blown or breaker action(bypass)
  • Waveform: Pure sine wave
  • Transfer Time: Between AC mode and battery mode: 0ms
  • Transfer Time: Between AC mode and bypass mode: 4ms(typical value 2.5ms)
  • Efficiency: ≥83%
  • Model: 12V sealed VRLA maintenance free
  • DC Voltage: 36VDC
  • battery: 3x12V/7AH
  • Back up time(half load): 16min
  • Back up time(full load): 5min
  • Charge current(standard unit): 1A
  • Charge current(long time unit): 7A
  • Recharge time:90% capacity after 8hrs charging
  • Communication Interface: RS232; SNMP (optional)
  • LCD Indicator: 1. input voltage/frequency, battery voltage, output voltage/frequency, load watt/VA and percent, inverter temperature. 2.Operation mode such as "on line", "on batt", or " or bypass"
  • LED Indicator: 1. Green LED for normal operation, 2. Yellow LED for warning condition, 3.Red LED for abnormal operation
  • Noise Level: <45dB
  • Temperature: 0⁰C - 40⁰C
  • Humidity: 0% - 95%(non-condensing)
  • Altitude: <1500m
  • Storage temperature: −25⁰C - 55⁰C
  • Standard unit Net/Gross weight (kg): 34/36
  • Long time unit Net/Gross weight (kg): 15/17
  • Dimension (W*D*H)mm: 191x478x339
  • Packing Dimension (W*D*H)mm: 332x603x482

Write a review